Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
52542 | SYSTRON-DONNER CORP MICROWAVE/INSTRU |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWJS | WINDING OPERATING VOLTAGE | 130.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST PRIMARY |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABHP | OVERALL LENGTH | 9.500 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CBME | CUBIC MEASURE (NON-CORE) | 277.9 CUBIC INCHES |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 6.500 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 28.000 POUNDS |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 250.0 VOLT-AMPERE SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 118.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 4.501 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 260.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND PRIMARY |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |